ASSE 5110 Backflow Tester Recertification

ASSE 5110 Backflow Tester Recertification

Backflow | Available

3/7/2025 (one day)
8:00 AM-4:00 AM on Fri
$675.00 USD

ASSE 5110 Backflow Tester Recertification

Backflow | Available

The purpose of this 8-hour ASSE Backflow Prevention Assembly Tester Recertification (5110), a part of the 5000 series, is to re-certify individuals who are equipped and prepared to ensure a swift and thorough field response as it pertains to the testing of multiple types of backflow prevention assemblies.

The goal of the course is to promote best practices in the field from legal obligations to practical knowledge. Fire University seeks to guide trainees through the process of theory and hands-on instruction. To accompany the classroom training, the trainee will also work their way through a series of tests on multiple types of backflow prevention assemblies.

After completing this course, trainees will be prepared, from a legal obligation to a practical knowledge standpoint, to carry out the responsibilities of a backflow preventer tester. 

Instructor

David Hahn - Nationally Recognized Instructor

Learning Objectives

At the conclusion of this course, trainees will be able to…

  • Articulate the principles of backflow prevention and cross connection control
  • Recognize testable and non-testable backflow preventers
  • Understand and test a wide variety of backflow preventers
  • Identify failures and proper course of corrective action
  • Properly document all information as it pertains to the testing of backflow preventers

Assessment

Trainees are expected to pass a practical exam and a 2-hour exam. Each trainee will have one and a half hours to complete the practical exam. The practical exam will consist of testing four assembly types, with at least one set up in failure mode. Assembly types that will be tested include Reduced Pressure Principle Backflow Preventer Assembly (1013), Double Check Backflow Prevention Assembly (1015), Pressure Vacuum Breaker Assembly (1020), Spill Resistant Vacuum Breaker Assembly 1056